Utilizing ambulatory electrocardiogram monitoring to reduce conduction related death after transcatheter aortic valve replacement - PubMed
Source : https://pubmed.ncbi.nlm.nih.gov/34851550/
doi: 10.1002/ccd.30027. Online ahead of print. 1 Department of Surgery, Division of Cardiac Surgery, Robert Wood Johnson University Hospital, New Brunswick, New Jersey, USA. 2 Rutgers Robert Wood Johnson University...
Conclusion/Relevance: Utilizing ambulatory electrocardiogram monitoring to reduce conduction related death after transcatheter aortic valve replacement
Predictive Model for Thrombus Formation After Transcatheter Valve Replacement - Cardiovascular Engineering and Technology
Source : https://link.springer.com/article/10.1007/s13239-021-00596-x
Purpose Leaflet thrombosis is a significant adverse event after transcatheter aortic valve (TAV) replacement (TAVR). The purpose of our study was to present a semi-empirical, mathematical model that links patient-specific...
Conclusion: A predictive model relating likelihood of valve thrombosis using Г in the NS was developed with promising sensitivity and specificity. With further studies and improvements, this predictive technology may lead to alerting physicians on the risk for thrombus formation following TAVR.
The impact of hypo-attenuated leaflet thickening on haemodynamic valve deterioration following transcatheter aortic valve replacement - PubMed
Source : https://pubmed.ncbi.nlm.nih.gov/34852974/
1 Monash Heart, Monash Health and Monash Cardiovascular Research Centre, Monash University, Australia. Electronic address: [email protected]. 2 Sussex Cardiac Centre, University Hospital Sussex NHS Trust, Brighton, United Kingdom. 3 Monash...
Heart Rate Induced Dynamic Coronary Ischemia Secondary to Aortic Valve Insufficiency from a Diminutive Aortic Valve Leaflet: Diagnosis and Repair - PubMed
Source : https://pubmed.ncbi.nlm.nih.gov/34820700/
Hemodynamically significant congenital obstruction of the coronary arteries is a rare phenomenon. The potential etiology of these obstructions is variable including coronary os stenosis, occlusive fibrous webs, or a dysplastic...
Conclusion/Relevance: We present a case of an infant presenting in heart failure secondary to dynamic coronary artery insufficiency from a diminutive aortic valve leaflet and aortic sinus and variable levels of aortic valve insufficiency based on heart rate.
A Sneak-Peek into the Physician's Brain: A Retrospective Machine Learning-Driven Investigation of Decision-Making in TAVR versus SAVR for Young High-Risk Patients with Severe Symptomatic Aortic Stenosis - PubMed
Source : https://pubmed.ncbi.nlm.nih.gov/34834414/
Transcatheter aortic valve replacement (TAVR) has rapidly become a viable alternative to the conventional isolated surgical aortic valve replacement (iSAVR) for treating severe symptomatic aortic stenosis. However, data on younger...
Conclusion/Relevance: Our study demonstrates a viable application of ML-based approaches for studying and understanding complex clinical decision-making processes.